APPLICATIONS AFS

AFS Pump Basin Distribution Valve Assemblies are designed to automatically redirect the pumps flow to multiple zones in a distribution field. Distribution Valves allow the use of a smaller horsepower pump to be used since flow can be divided by number of zones. All internal plumbing is assembled prior to shipment, saving valuable time in the field.



SPECIFICATIONS

Riser Pipe Material: 24” PVC KOR FLO™ or 30” PVC Perma-Loc™ Riser Pipe
Base Material: FRP encapsulated wood core epoxy bonded to riser pipe
Access Cover Material: FRP encapsulated wood core with Neoprene gasket and stainless steel fasteners
Distribution Valve: Orenco Automatic Distribution Valve
Flow Range: 10-40 GPM (44 Series), 10-25 GPM (46 Series), 15-100 GPM (64 or 66 Series)
Discharge Size: 1.25” (44 & 46 Series) or 1.5” (64 & 66 Series)

FEATURES

♦ Flex Hose
♦ Mechanically Operated
♦ Ball Valve
♦ Schedule 40 Fittings
♦ Schedule 80 Unions
♦ 24” PVC KOR FLO™ Riser Pipe
♦ Stainless steel lid fasteners and wrench included with lid

OPTIONS

♦ 2-6 Outlet zones allowing for 10-100 GPM
♦ 1.25” or 1.5” SCH40 PVC discharge pipe and fittings
♦ Insulated lid
♦ 30” PVC Perma-Loc™ Riser Pipe (66 Series)

MODEL NUMBERS

AFS-----------AUTOMATED FLOW SYSTEMS
PBDV-----------PUMP BASIN DISTRIBUTION VALVE
24-----------BASIN DIAMETER (24 = 24") (30 = 30")
48-----------BASIN HEIGHT (INCHES) (48" STANDARD)
V44-----------DISTRIBUTION VALVE SERIES (V44, V46, V64, V66)
02-----------NUMBER OF ZONES (2-6)

DRAWINGS